示例案例
Water pooling under the kitchen sink
Kitchen · Plumbing
你描述的情況: A slow drip from the curved pipe under the sink; the cabinet floor is damp and a bucket fills about an inch overnight.
較可能是什麼
Most likely a worn P-trap slip-joint washer or a loose compression nut. This is the single most common under-sink leak — and one of the few plumbing jobs that is genuinely DIY-friendly: no soldering, no supply-line pressure once the valves are off.
決定
Do it yourself. Parts are under $20 and the job takes about half an hour.
預覽版。不會上傳照片,服務器也不做診斷。
自己做
$10–$25 in parts · 30–45 minutes
動手前 — 先做安全檢查
- • Confirm the leak has not reached any outlet, cord, or appliance under the sink. If water is touching anything electrical, do not reach in — stop and call a pro.
- • Check that both shut-off valves turn by hand. A valve that is stuck, crumbling, or already leaking is on the pressurized supply side — stop here; replacing it is a plumber job.
- • If the leak is getting worse quickly, or the cabinet floor feels soft, swollen, or rotten, skip the DIY steps and call a plumber.
- 1Turn both shut-off valves under the sink clockwise until they stop. Run the faucet to confirm the water is off.
- 2Put a bucket under the P-trap (the U-shaped pipe) and loosen the two big plastic nuts by hand — expect a cup or two of water.
- 3Slide the trap off. Check the thin beveled washers on each joint; a cracked or flattened washer is almost always the culprit.
- 4Take the old washer to the hardware store and match it exactly (1-1/2 in is standard for kitchen sinks). Replace both washers while you're in there.
- 5Reassemble hand-tight, then a quarter-turn more with pliers — no more. Overtightening cracks the nuts.
- 6Turn the water back on, run the faucet for two minutes, and feel every joint with a dry paper towel. Any dampness means reseat that joint.
工具和零件
- • Bucket
- • Slip-joint pliers
- • Replacement P-trap washer kit (1-1/2 in)
- • Paper towels
- • Flashlight
安全線
- • Shut the water off first — always. If a shut-off valve itself leaks or won't turn, stop: that valve is on the pressurized supply side and is a plumber job.
- • No chemicals needed. Skip drain cleaner for a leak — it isn't a clog problem.
出現這些情況就停,改叫師傅… Call a plumber instead if: the leak is at the shut-off valve or the wall stub-out, you see mold or cabinet rot spreading, or the drain line itself is cracked. Austin plumbers typically charge $150–$300 for a trap replacement visit (sample range).
價格區間是本預覽用的奧斯汀示例數據(示例數字,截至 2026 年 10 月)。
僅供參考。拿不準時,找持證師傅是一個成立的決定。