샘플 사례

This week — tonight if anyone at home is elderly or has health risks직접 수리 난이도: Checks: 1 / 5 · Repair: not DIY

AC runs all day but the house won't cool

HVAC · Cooling

알린 내용: Thermostat set to 74°F, house stuck at 79°F by mid-afternoon. Air from the vents feels weak and only slightly cool. It's 101°F outside — peak Austin summer.

가장 가능성 있는 원인

Three causes cover most cases: (1) a clogged air filter starving airflow, (2) a dirty outdoor condenser coil, or (3) low refrigerant from a slow leak. The filter is a free check you can do yourself, and a dirty coil is easy to spot from outside — but cleaning the coil is a technician job, not a hose job. The third cause is licensed work outright — refrigerant handling is regulated, and it is never a DIY fill-up.

결정

Run the two free checks first (20 minutes). If neither fixes it, call an HVAC tech — don't open the system yourself.

미리보기입니다. 사진은 올라가지 않고, 서버에서 진단도 하지 않습니다.

직접 하기

$0–$20 for a filter · 20 minutes of checks

  1. 1Check the filter first. Pull it out and hold it up to a light — if you can't see light through it, replace it. In Austin summers a filter can clog in a month.
  2. 2Confirm the thermostat is on Cool, fan on Auto, and set 3–4 degrees below room temperature. Replace its batteries if it has them.
  3. 3Outside, look at the condenser (the big fan unit) without opening anything: clear leaves and grass at least 2 feet around it so air can move. If the fins look matted with dirt, note it for the technician — a technician will clean the condenser coil; do not hose it down yourself.
  4. 4Feel the vent air again after an hour. Cool and stronger? You found it. Still weak or warm? Stop here and call a pro.

도구와 부품

  • • Replacement air filter (check the size printed on the old one)
  • • Work gloves (for clearing leaves and debris)
  • • Flashlight

안전 선

  • • Do not open the unit's panels and do not touch electrical parts — not even with the breaker off. Anything that needs the cover opened, a wire touched, or a breaker thrown is a stop point: stop and hand it to an HVAC technician.
  • • Never open the refrigerant lines or the electrical panel inside the unit — capacitor shock is a real risk even with power off. That side is licensed-tech only.

전문가 부르기

$89–$150 diagnostic visit in Austin; common minor repairs (capacitor, contactor) $200–$450 total (sample ranges)

누구를 부르나: Licensed HVAC technician

예약 전에 물을 것

  • ▸“Is the diagnostic fee waived if you do the repair?” — many Austin shops waive it; ask before booking.
  • ▸“Show me the failed part and the reading that proves it failed.” — a capacitor reading takes ten seconds to show you.
  • ▸“Is this a repair or is the unit at end of life?” — if the quote jumps past $1,500 on a unit over 12 years old, get a second quote before signing.

In a Texas heat wave, book the first available slot and ask to be put on the cancellation list — same-day slots open up by mid-morning.

가격 범위는 이 미리보기용 오스틴 예시 데이터입니다(예시 수치, 2026년 10월 기준).